DM9200
Digital Precision Manometer

Product Description

May 18, 2009

DM9200

Suitable for continuous measurement of pressure, low pressure and
differential pressure in non-aggressive gases such as gas flow pressure,
combustion chamber pressure or chimney draft.

Measurement Ranges

Standard: ± 350 hPa (mbar) or….
± 1000 hPa (mbar) or….
± 130 hPa (mbar)
High precision: ± 75 hPa (mbar) and….
± 750 Pa

Features

  • Micro processor controlled piezoresistive pressure sensor
  • Zero point adjustment through software
  • Pressure unit selection in hPa, mbar, bar, psi, mm Hg, inch Hg, cm H2O, inch H2O
  • Automatic temperature compensation through micro processor
  • Legible LCD display
  • Infrared interface for printer
  • Measured data memory for 20 measurements
  • Minimum/maximum value memory
  • Programmable average value calculation
  • ABS case with rear magnetic plate
  • Benefits

  • Compact and lightweight for easy handling; large display for easy operation
  • Logical software; all functions operated by only 3 keys
  • Print and memory functions ensure data integrity
  • Programmable averaging smoothes widely fluctuating vales in the Pa range
  • High precision version with stable long-term sensor particularly well suited for very sensitive low pressure range
  • Technical

  • Measurement Range:
  • ± 75 hPa (mbar)
  • -99.9 Pa to 750 Pa (Resolution 0.5 Pa)
  • -750 Pa to -100 Pa (Resolution 1.0 Pa)
  • 7.5 hPa to 75.00 hPa (Resolution 3.0 Pa)

  • Display in Pa up to 750 Pa, and from 7.5 hPa to 75 hPa it is in hPa, with automatic switchover.
  • Precision: ± 1 % FS
    Repeatability: ± 1 % FS
  • Measurement Range:
  • ± 130 hPa
  • -130 hPa to 130 hPa (Resolution 0.1 hPa)
  • -20 hPa to 20 hPa (Resolution 1.0 hPa)
  • Precision: ± 2 % FS
    Repeatability: ± 0.5 % FS
  • Measurement Range:
  • ± 350 hPa
  • -350 hPa to 350 hPa (Resolution 1.05 hPa)
  • Precision: ± 2 % FS
    Repeatability: ± 1 % FS
  • Measurement Range:
  • ± -999 hPa to 1000 hP
  • -999 hPa to 1000 hP (Resolution 1.0 hPa)
  • Precision: ± 2 % FS
    Repeatability: ± 1 % FS
  • Media:
  • All non-aggressive media

  • Connection pressure/low pressure:
  • Hose coupling
  • 0.3” (8.0 mm)
  • Silicone hose
  • 0.23” x 0.08” (6 x 2 mm)
  • + for pressure
  •  
  • - for low pressure
  •  
  • Power supply:
  • 2 x Mignon LR6 AA batteries
  • Operating temperature:
  • 40° F to 100° F (5° C to 40° C)
  • Storage temperature:
  • 14° F to 120° F (-10° C to 50° C)<
    /td>
  • Case:
  • ABS case with rear magnetic plate
  • Dimensions:
  • 3.3” x 5.5” x 0.9” (84 x 139 x 24 mm)
    w x h x d
  • Weight:
  • Approx. 9 oz (250 g)