• Germany
  • Austria
  • Italy
  • Russia
  • Czech Republic
  • Slovenia
  • Poland
  • Turkey

MGA luxx

Heavy duty flue gas
emission analyzer
for long time measurements of
industrial combustions, large boilers,
gas engines and turbines,
furnaces and many more

COMING SOON!

  • Precise measuring technique using non dispersive infrared (NDIR) technique
  • Remote display through MRU4U App over bluetooth on smartphone or tablet or trough VCN server via LAN/WLAN
  • Up to 6 gas NDIR measurement:
    CO/CO2/HC/SO2/NO/NO2 and oxygen with either long-life O2-ECS or
    O2-PM (paramagnetic cell)
  • 7” high-resolution (800×480 pixel) TFT color display with swipe and touch technique as for smartphones, with LINUX operating system
  • Intuitive icons and country specific language on display
  • Modern and robust design, Aluminum enclosure with rubber molded impact
    protection for use in harsh industrial environment
  • Advanced algorithms to control analyzer’s operation, like warming up, compensation of cross-sensitivity values, response time – all which have impact on the quality and performance
  • Measurement of many additional parameters:
    temperatures (ambient and flue gas), pressures (atmospheric and differential),
    internal sample flow monitoring
  • Measurement of flue gas flow velocity (using of Pitot tube) and calculation of
    stack gas flow rate
  • Calculation of all combustion parameters like:
    heat loss, combustion efficiency, excess air coefficient, dew point temperature and others
  • Results stored in database – possibility to view entire measurement session in graphical form, create measurement reports, export data to CSV files, and more
  • PC communication via LAN – Ethernet
  • Wireless data transfer via Bluetooth dongle or WLAN dongle
  • Long distance data transfer via RS485 cable
  • Analog outputs (8-channels), analog inputs (4-channels)
  • SAMPLE GAS CONDITIONING: Dual gas cooler (Peltier) with dual condensate
    draining pumps, with constant dew point +5°C
    when connected to mains power supply
  • Condensate monitoring and alarm on display
  • Strong gas sampling pump, regulated flow of approx 1l/min
  • Gas sampling probe heated, with exchangeable probe tubes, including K-type thermo-couple for flue gas temperature measurement
  • Heated sampling line, Teflon 6/4mm, 9.84′ or 16.4′ or 32.81′ (3 m – 5 m – 10 m) and other lengths
TECHNICAL DATA
Gas measurement Method Meas. range

(0…min / max)

Resolution Accuracy **
O2 – Oxygen ECS 0 to 25.00 % 0.01 % 0.2 %
O2 – Oxygen PM 0 to 25.00 % 0.01 % 0.1 %
CO2 – Carbon monoxide NDIR 0 to 5 / 40% 0.01 % ± 0.2 % or 2 % reading
CO – Carbon dioxide NDIR 0 to 1,000 / 10,000 ppm 1 ppm ± 20 ppm or 2 % reading
HC – Hydrocarbons as CH4 NDIR 0 to 1,000 / 10,000 ppm 1 ppm ± 20 ppm or 2 % reading
HC – Hydrocarbons as C3H8 NDIR 0 to 1,000 / 10,000 ppm 1 ppm ± 10 ppm or 2 % reading
NO – Nitric oxide NDIR 0 to 1,000 / 4,000 ppm 1 ppm ± 20 ppm or 2 % reading
NO2 – Nitrogen dioxide NDIR 0 to 500 / 1,000 ppm 1 ppm ± 10 ppm or 2 % reading
SO2 – Sulfur dioxide NDIR 0 to 1,000 / 4,000 ppm 1 ppm ± 10 ppm or 2 % reading
HC – Hydrocarbons as CH4 NDIR 0 to 1,000 / 4,000 ppm 1 ppm ± 20 ppm or 2 % reading
H2S – Hydrogen sulfide ECS 0 to 2,000 / 5,000 ppm 1 ppm ± 10 ppm or 2 % reading
H2 – Hydrogen ECS 0 to 1,000 / 2,000 ppm 1 ppm ± 5 ppm or 2 % reading
OTHER MEASUREMENTS / CALCULATIONS Method Measuring range
Tgas – stack gas temperature NiCrNi 32°F to 2.192°F K-type
Tair – combustion air temperature NiCrNi 32°F to 932°F K-type
Tamb – ambient air temperature RTD 32°F to 212°F PT2000
Diff.pres. – differential pressure Piezoresistive -48 to +48 inH2O
GasFlow – flow velocity – differential pressure Pitot 3 … 100 m/s
AUX – auxiliary connector –

standardized external signal

Software for K-thermocouple, 0 … 10 Vdc , 4 … 20 mA, RS485
Combustion calculations – fuel type dependent Software heat loss, ExcAir, Air Ratio (λ), dewpoint
Emission calculations Software mg/Nm3 , reference to O2 , g/kWh, g/s , kg/h
GENERAL TECHNICAL DATA  
Operating system LINUX
Display, operation 7“ TFT (800 x 480 px) colour display, backlit, with touch pad
Data storage type /capacity internal 10.000 data sets, external USB stick
Interface to external PC/notebook Ethernet, Bluetooth, WLAN, RS485
Cable communication interface RS485, RJ45 (Ethernet)
Wireless communication Bluetooth, WLAN
Thermal printer external only
Analog output 4 – 20 mA/analog input 4 – 20 mA 8 channel out / 4 channel in/user configurable
Universal analog input – AUX – 0…10 Vdc / 4…20 mA / NiCrNi / RS485
System warming up time 30 minutes (typical)
Warming up temperature NDIR bench 131°F (55 °C)
Mains free operation time / stand-by only 1 hour
Internal battery Li-Ion , 96W, for standby
Operating conditions 41°F to 113°F, RH up to 95% non condensing
Storage temperature -4°F to 122°F
Power supply / consumption 86 to 265 Vac / 47…63 Hz / 105 W (analyzer only)
Enclosure material aluminum, rubber molded impact protection
Protection class IP20 (or IP42 inside transport case)
Dimensions 16.92“ x 11.41“ x 5.9“ (WxHxD)
Weight from 16.5 lbs. for minimal configuration

* overload range of ECS is usable only for short duration

** which ever is larger