VARIO luxx SYNGAS

NO LONGER AVAILABLE !!

The VARIO luxx is the replacement analyzer.

VARIO luxx SYNGAS W I T H
• Modern, rugged aluminum enclosure with rubber molded impact protection
• Linux OS & large, high-contrast and backlit 7″ (840×480) graphical display
• Display with easy, intuitive touch panel and all measured data at one sight
• Graphical data visualization, csv or pdf reporting file
• Data transfer to PC over LAN Ethernet (RJ45 socket) or USB
• Calculation of “balance” N2 and also of syngas calorific value
• Syngas inlet port with safety orifice, to reduce sample flow to max 1 L/min
• Monitored enclosure fan to increase safety in operation
• Integrated, efficient electrical Peltier gas cooler
• Automatic condensate draining via condensate pump
• Internal sample flow volume measurement
• Automatic zeroing by means of 3-way solenoid valve
• Strong, regulated sample gas pump
• Easy replaceable, effective PTFE filter
• Zero gas (ambient air) inlet port
• Sample gas evacuation over VENT outlet port
• Automatic internal test and control of soft- and hardware functions
• Automatic measurement incl. data logging function
• 10,000 data of internal data storage and large data storage on external 4GB USB-stick (MRU design)
• Syngas temperature measurement up to 2,192°F (1.200°C )
• Differential pressure measurement +/- 100 hPa
• 8 channel analog output 4-20mA and 4 channel analog input 4-20mA
• Universal analogue input (AUX socket) with 0-10 V or 4-20 mA signal or K-thermocouple or RS485
• 1 hour Li-Ion 48Wh battery stand-by operation, with power supply for gas cooler and heated probe filter
• Universal power supply: mains 90-264 Vac/ 105 W (up to 600W with 5m heated sampling line)
• Soft padded nylon transport case with compartment for accessories
Prepared for options such as:
•  O2 measurement using either long-life electrochemical cell or paramagnetic cell
• Reduced sample gas flow, adjustable from 10 to 30 l/h, for small scale lab tests
• Wireless data transfer and display to smartphone or tablet with MRU4u app
• Temperature regulation of heated gas sampling line (only possible with AC grid power supply)
Measurement components Method Meas. range (0…min / max) * Resolution Accuracy **
O2 Oxygen (long-Life) ECS 0 … 25.00 % 0.01% 0.2%
O2 Oxygen PM 0 … 25.00 % 0.01% 0.1%
H2 Hydrogen TCD 0 – 10% / 30% / 100% 0.01% ± 0.2 % / 2% measuring value
CO Carbon monoxide NDIR 0 … 100 % 0.01% ± 0.5 Vol %
CO2 Carbon dioxide NDIR 0 … 100 % 0.01% ± 0.5 Vol %
CH4 Methane NDIR 0 … 100 % 0.01% ± 0.5 Vol %
H2S Hydrogen sulfide ECS 0 … 2,000 / 10,000 ppm 1 ppm ±10 % (0 to 500ppm) 15% > 500ppm
* overload range of ECS is usable only for short duration ** which ever is larger *** with hourly zeroing